Advice on adding a LPG Gas Boiler on Central Heating System with a Hot Water Storage Tank heated with Solar Panels

by Denis Shrestha   Last Updated May 01, 2018 10:21 AM

I am from Kathmandu, Nepal, and presently trying to install a central heating system in my house using Solar Water Heater. Background: Winter days in Kathmandu lasts about 130 days a year. Minimum temperature during the night is Zero degrees Celcius and During the Day time is 18 degrees (C). Out of 130 winter days, 120 days are sunny days (6 to 7 hours every day). Solar hot water heating systems for Domestic Hot water are very popular and have been in use already more than 2 decades successfully. I am going to use the similar system to heat the water and store in a storage tank and circulate it through radiators through out the winter. This new system will be used solely for heating purpose and NOT for Domestic Hot Water.
After careful calculation of Heat requirements and Radiator planning for every room, I have decided to have a 1000 liter hot water storage tank and 5 solar panels to heat the water on my roof top (have ample of space on my roof for this). Water temperature is easily heated to 70-80 degrees (C) solely by solar panels. This water will circulate in the radiators and back to storage tank. In my approximate calculation the 1000 liter tank will keep my house warm till 3 am in the morning, and then the water temperature will go down, as there is no sun during the night and also during cloudy days. From that point, I wanted to install a LPG Gas Boiler to heat the water. I got into few confusion on where to install the Boiler: Option 1. Shall I install it bypassing the storage tank thus boiler needs to heat only the volume circulation in the radiators and not the whole 1000 liter tank? Option 2. Shall I install it to heat the water inside the storage tank and heat the whole water? Option 3. Water from Storage tank flows through Boiler then to Radiators. Boiler is controlled by Room Thermostat. But not sure if the water can still flow when Boiler is not running. (Diagram Attached) I have 2 thermostats in the room as a reference of temperature. One thermostat to stop the Circulating pump if Room Temperature is more than 24 degrees (C). 2nd Thermostat is to start Gas Boiler if the Room Temperature falls below 16 degrees (C). The problem I am facing if I choose Option 1: the Boiler will start when temperature drops below 16 degrees. Then I do not need to run the Circulating Pump - how to turn it off. And vise versa? I am attaching a diagram for the reference on what I am planning to do. Any help and if anyone had an experience with similar installation would be a really great help. Presently during winter days - we are using Fireplace in the Sitting Room and everyone gathers around it in the evening, while remaining house is cold with as less as 9 degrees (C). Thank you all in advance![enter image description here]1



Related Questions



Solar powered thermal ballast - is it feasible?

Updated September 18, 2017 12:21 PM


When should HVAC returns be opened and closed?

Updated August 04, 2017 02:21 AM

Is it a bad idea to disconnect the my radiator fan?

Updated November 01, 2017 14:21 PM